Optical analysis of chemical properties

Endress+Hauser

Endress+Hauser KRCT Raman Calibration Tool

Spectral intensity referenceNIST SRM glassMeasuring principleRaman spectroscopyTemperatureOperating: -20 to 50 °C / -4 to 122 °FRecommended storage: 15 to 25 °C / 59 to 77 °FRelative humidityRecommended storage: < 10 % humidity, non-condensingUnit...

Endress+Hauser

Endress+Hauser KRC Raman Rxn2 mobile cart

Unit dimensions (width x height x depth)Cart:685 × 1022 (tabletop) × 753 mm26.97 × 40.24 (tabletop) × 29.65 inchShipping crate: 902 x 1549 x 1276 mm35.52 x 60.99 x 50.24 inchWeightCart: 59 kg / 130 lbsShipping crate: 179 kg / 395 lbs, depending on cart...

Endress+Hauser

Endress+Hauser KR46 Raman Rxn-46 probe

Sample interfaceTemperature: probe is non-contact; operating temp: 10 to 50 °C / 50 to 122 °F Measuring principleRaman spectroscopySpectral coverageProbe spectral coverage is limited by the coverage of the analyzer being used.Maximum laser power into...

Endress+Hauser

Endress+Hauser KR45 Raman Rxn-45 probe

Wetted materialsBody: 316L stainless steelWindow: Proprietary material, optimized for bioprocessesProcess connection: PG13.5 for industry standard sensor housings, welded port connectors availableSurface finish: Ra 15 with electropolishAdhesive: USP...

Endress+Hauser

Endress+Hauser KR41 Raman Rxn-41 probe

Wetted materials316L optionMetal: 316L stainless steelWindow: High-purity sapphireC276 optionMetal: C276 alloyWindow: High-purity sapphireTitanium optionMetal: Grade 2 titaniumWindow: High-purity sapphireHybrid metal combination optionMetal: 316L...

Endress+Hauser

Endress+Hauser KR40 Raman Rxn-40 probe

Wetted materialsMetal: C276 alloy, 316L stainless steel, or Grade 2 titaniumWindow: High-purity sapphireHazardous area certificationsATEX, CSA, IECExMeasuring principleRaman spectroscopySpectral coverageProbe spectral coverage is limited by the coverage...

Endress+Hauser

Endress+Hauser KR30 Raman Rxn-30 probe

Hazardous area certificationsATEX, CSA, IECExMeasuring principleRaman spectroscopySpectral coverageProbe spectral coverage is limited by the coverage of the analyzer being used.TemperatureTemperature, Rxn-30 probe: -20 to 150 °C / -4 to 302 °FRelative...

Endress+Hauser

Endress+Hauser KR20 Raman Rxn-20 probe

Body and window materialsBody: 316L stainless steelWindow: optical-grade materialsHazardous area certificationsATEX, CSA, IECExMeasuring principleRaman spectroscopySpectral coverage175-1890 cm-1 (785 nm)TemperatureTemperature, Rxn-20 probe: 10 to 40 °C /...

Endress+Hauser

Endress+Hauser KR10 Raman Rxn-10 probe

Body and window materialsRxn-10 probe body: 6061 aluminum, 316L stainless steel, and 303 stainless steelMeasuring principleRaman spectroscopySpectral coverageProbe spectral coverage is limited by the coverage of the analyzer being used...

Top